Most people don't realise this is possible. If your gas ducted heater sits outside the house or under the floor, we can swap it for an all-electric system that uses the exact same ducts and vents, and it cools as well as heats. You go from a heater that only works in winter to whole-home heating and cooling, without new ductwork, without holes in your ceilings, and usually in a single day.
Tell us about your current heater. We'll come back to you with a straight answer.
If your gas ducted heater sits outside the house or under the floor, this is the simplest way to go all-electric and pick up cooling at the same time, using the ducts already in your home.
Going from gas ducted heating to electric usually means a full ducted reverse cycle retrofit. New ductwork, new vents, holes in your ceilings, a plasterer, a painter, and the better part of a week with your house pulled apart. That is why most people put it off.
The Braemar Dominator Series was built to avoid all of that. It is an all-electric reverse cycle system packaged to sit in the exact position your old gas heater came out of, and it connects into the ductwork and ceiling vents already in your home. For houses with the heater outside or under the floor, it is a straight swap.
To be upfront about what is involved: we upsize your return air, run a new return air duct and a new supply duct, and replace the first fitting. That work is included in the price below. Everything else stays as it is.
That is what you pay, not a headline before rebates. The $4,500 Victorian Energy Upgrades discount has already been taken off, and it is applied to your quote up front so there is nothing for you to claim back. Final price depends on your home, and we confirm it in writing before any work starts.
This system suits a specific setup. Rather than have you book a quote and find out it is not for you, here is how to tell in about ten seconds.
This is for heaters mounted outside the house or under the floor. That is where the Dominator makes the most sense and where the savings are real. If your heater is up in the roof space, we would fit a conventional ducted reverse cycle system instead and we will tell you so.
For an underfloor install you need roughly 500mm of clearance beneath the floor. If your heater already sits outside, clearance is not an issue at all. Not sure? Send a photo through and we will tell you on the spot.
The usual objection to going electric is that heat pumps go soft when it actually gets cold. Out here that is a fair question, and this is the answer to it.
Rated to keep producing heat at ambient temperatures as low as minus fifteen. Frosts in Woodend, Trentham and Mount Macedon are not going to trouble it.
Rated at 17.0kW with a heating range from 5.4 up to 21.0kW, driven by a micro-channel heat exchanger designed specifically to maximise heating capacity and efficiency.
The Dominator was designed to work alongside an existing evaporative cooler. Hyper-efficient evap through summer, real warmth in winter, and refrigerated cooling on the handful of humid days evap struggles with.
Seeley's Black Magic coating on the outdoor coil gives three times the corrosion protection of blue fin, which matters on exposed rural blocks.
Optional zone control covers 4 to 8 zones with individual temperature and time schedules, and a SAVE function that caps the temperature range so the running costs stay sensible.
Braemar has been an Australian brand since 1938 and Seeley International is the country's largest air conditioning manufacturer. Five year comprehensive warranty and a national service network.
Braemar confirm the Dominator Series is a direct replacement for every major ducted gas heater brand you will find in a Macedon Ranges home.
Still limping along on an old unit? Look up what it is telling you first on our heater error code guides, then give us a call.
The full figures, so you can compare it properly against anything else you are being quoted.
| Specification | Figure |
|---|---|
| Rated heating capacity | 17.0 kW (range 5.4 to 21.0 kW) |
| Rated cooling capacity | 13.2 kW (range 2.3 to 16.8 kW) |
| Heating operating range | -15°C to 24°C ambient |
| Cooling operating range | -15°C to 52°C ambient |
| ACOP / AEER | 3.49 / 3.37 |
| Power supply | 220 to 240V, single phase |
| Rated current | 32 A |
| Rated airflow | 700 l/s (range 400 to 900 l/s) |
| External static pressure | 0 to 300 Pa |
| Refrigerant | R32, 4.5 kg base charge |
| Indoor unit size | 1148 × 530 × 802 mm, 62 kg |
| Outdoor unit size | 940 × 320 × 1430 mm, 117 kg |
| Max pipe run / height | 75 m / 30 m |
| Condensate pump | Built in, 1 m lift |
| Models | Indoor KGHV200A1S / Outdoor KCHV160D1B |
| Warranty | 5 year comprehensive |
A note on sizing, because it matters. At 17kW this suits most homes, but using the Victorian Government's own guide of 1.1 to 1.4kW per 10 square metres, it comfortably covers roughly 120 to 155 square metres of ducted area. If your home is larger than that we will tell you honestly and look at other options rather than undersize you.
Same job, same price, across the surrounding towns.
Send us a photo of your existing heater and your suburb. We will tell you straight away whether the Dominator is the right call for your place, or whether something else suits you better.
Our service area runs along the Hume Highway up to Broadford, west across to Heathcote and Castlemaine, down through Daylesford, Creswick and Ballarat, then across Meredith, Bacchus Marsh and Melton, and back to Sunbury. Everything inside this line, we do. Sitting just outside it? Give us a call and we will let you know.
Check your suburb