    Bonaire

    Bonaire ducted heating error codes

    A full list of Bonaire gas ducted heater fault codes and what each one means.

    Bonaire heaters flag faults with a numbered code on the controller. Below is every code with a plain-English meaning. Common ones include flame faults, pressure losses, gas valve errors and overheats, many of which we can sort on the first visit. If you see a code, switch the unit off and book a licensed technician rather than resetting it repeatedly.

    Code Lookup

    Bonaire error codes

    Type your code in the box to jump straight to it, then tap Book to send it through with your details.

    Error 2
    Overheat prevention or outlet temperature too high
    Error 3
    Overheat detected by thermistor or overheat switch
    Error 4
    Temporary parameter storage fault
    Error 6
    Pressure lost after combustion fan operation check
    Error 8
    Flame not detected during ignition
    Error 9
    Flame unstable or flame out immediately after ignition
    Error 10
    Flame lost during heating
    Error 11
    Shutdown due to transient problem
    Error 12
    Thermostat on at power-up
    Error 13
    Condensate detected (6-star heaters)
    Error 14
    Condensate sensor short or open circuit (6-star heaters)
    Error 15
    System timing error, mains frequency not 50Hz or internal control fault
    Error 16
    Modulating valve overcurrent
    Error 17
    Thermistor location fault
    Error 18
    Thermistor open circuit
    Error 19
    Thermistor short circuit
    Error 20
    Overheat switch or thermistor fault after cooldown
    Error 21
    Too many overheats from overheat switch
    Error 22
    Too many combustion fan drive errors or possible flue restriction
    Error 23
    Pressure detected in idle state
    Error 25
    Pressure not detected during initial combustion fan test
    Error 26
    Too many pressure losses
    Error 27
    Low 24V AC
    Error 28
    Too many overheats from thermistor
    Error 29
    Flame sense fault
    Error 30
    Too many ignition attempts
    Error 31
    Too many flame validation attempts
    Error 32
    No 24V AC
    Error 33
    Modulating valve open circuit
    Error 34
    Modulating valve short circuit
    Error 35
    Circulation fan drive fault
    Error 36
    Combustion fan drive fault
    Error 37
    AC input fault
    Error 38
    System error or A-D converter fault
    Error 39
    System error or MCU fault
    Error 40
    False flame detected with no gas
    Error 41
    Primary gas valve not on
    Error 42
    Primary gas valve stuck on
    Error 43
    Primary gas valve lost during run
    Error 44
    Secondary gas valve not on
    Error 45
    Secondary gas valve stuck on
    Error 46
    Secondary gas valve lost during run
    Error 48
    MCU communication error
    Error 49
    MCU communication fault
    Error 50
    Remote MCU not shut down
    Error 51
    Incorrect remote MCU state
    Error 52
    Mismatch in MCU information
    Error 53
    Unidentified or transient internal control fault
    Error 54
    Remote MCU lockout
    Error 55
    Unidentified or transient internal control fault
    Error 56
    Too many pressure losses
    Error 57
    Invalid model or model dongle fault
    Error 58
    Maximum number of resets exceeded
    No matching code found. Give us a call on 0482 085 538 and we will diagnose it.

    Other brands: Brivis & RinnaiBraemar

    Where We Work

    Servicing the whole Macedon Ranges

    From Gisborne to Kyneton, our technicians cover the Ranges and surrounds every week.

    Tap your suburb to start a quote

    Not sure if we cover your street? Give us a call. If it's in the Ranges, we're almost certainly there.

    Code you can't clear? Book a local repair

    Tell us the code and what the unit is doing, and we will call you back with a time and an upfront price.

    • Bonaire factory-level knowledge
    • Servicing the whole Macedon Ranges
    • Upfront, honest pricing
    Book a RepairCall 0482 085 538
    Inside the line, we service it. Just outside? Give us a call and we will let you know.
    Our Service Area

    Servicing the Macedon Ranges and central Victoria

    Our service area runs along the Hume Highway up to Broadford, west across to Heathcote and Castlemaine, down through Daylesford, Creswick and Ballarat, then across Meredith, Bacchus Marsh and Melton, and back to Sunbury. Everything inside this line, we do. Sitting just outside it? Give us a call and we will let you know.