    Braemar

    Braemar ducted heating error codes

    A full list of Braemar gas ducted heater fault codes and what each one means.

    Braemar heaters display a numbered error code when the control board detects a fault. Below is every code with a plain-English explanation. A lot of these, flame rollout, ignition failure, pressure switch and overheat faults, are common and often fixable on the first visit. If a code appears, turn the heater off at the controller and book a licensed technician.

    Code Lookup

    Braemar error codes

    Type your code in the box to jump straight to it, then tap Book to send it through with your details.

    Error 01
    Low pressure switch closed at start
    Error 02
    Low pressure switch failed to close
    Error 03
    Low pressure switch opened during run
    Error 04
    Thermistor above 70°C during run
    Error 05
    Thermistor short circuit or open circuit
    Error 06
    Flame detected when not required
    Error 07
    Ignition failure
    Error 08
    Condensate pressure switch closed at start
    Error 09
    Thermistor above 60°C during start
    Error 10
    Heat exchanger over-temperature circuit 1 open
    Error 11
    Loss of flame signal
    Error 12
    High pressure switch closed at start
    Error 13
    High pressure switch failed to close
    Error 14
    High pressure switch opened during run
    Error 15
    Thermistor in cool duct location or multiple over-temperature resets
    Error 16
    Thermistor in cool duct location or multiple over-temperature resets
    Error 17
    Condensate detected during run
    Error 18
    Condensate detected during start
    Error 19
    Heat exchanger over-temperature circuit 2 open
    Error 20
    Flame rollout detected during start
    Error 21
    Flame rollout detected during run
    Error 22
    Supply voltage out of range
    Error 23
    Room fan not running
    Error 24
    Room fan running backwards
    Error 25-29
    Data table flag incorrect or control data fault
    Error 30
    Loom ID incorrect
    Error 31
    Combustion air pressure detected before start
    Error 32
    Combustion air pressure too low at start
    Error 33
    High gas relay error
    Error 34
    Low gas relay error
    Error 35
    Flame rollout circuit check failed
    Error 36
    Flame rollout loom disconnected or shorted to ground
    Error 37
    Reset button stuck
    Error 38
    Gas valve closed during run
    Error 39
    Combustion air pressure sensor error
    Error 45
    Combustion air pressure too low during run
    Error 46
    Gas valve modulating coil outside range
    Error 47
    Combustion pressure sensor communication error
    Error 48
    Micro flame mismatch
    Error 49
    Five lockouts within 15 minutes
    Error 50
    MagIQtouch controller communication loss
    Error 51
    Microprocessor 2 error found
    Error 52
    System check memory error
    Error 53
    Voltage rail error
    Error 54-64
    Internal ICS or control board fault
    Error 70
    Micro one reading 1 at start-up or flame circuit reading too high
    Error 71
    Micro one reading 2 at start-up or flame circuit reading too high
    Error 72
    ICS flame circuit error, microprocessor 2
    Error 73
    Ripple value too high at start-up or flame sense reading too high
    Error 74
    Micro one reading 1 after pre-purge or flame sense reading too high
    Error 75
    Micro one reading 2 after pre-purge or flame sense reading too high
    Error 76
    ICS flame circuit error, microprocessor 2 after pre-purge
    Error 77
    Ripple value too high after pre-purge or flame sense reading too high
    Error 78
    Micro one reading 1 during start-up or flame sense reading too high
    No matching code found. Give us a call on 0482 085 538 and we will diagnose it.

    Other brands: Brivis & RinnaiBonaire

    Where We Work

    Servicing the whole Macedon Ranges

    From Gisborne to Kyneton, our technicians cover the Ranges and surrounds every week.

    Tap your suburb to start a quote

    Not sure if we cover your street? Give us a call. If it's in the Ranges, we're almost certainly there.

    Code you can't clear? Book a local repair

    Tell us the code and what the unit is doing, and we will call you back with a time and an upfront price.

    • Braemar factory-level knowledge
    • Servicing the whole Macedon Ranges
    • Upfront, honest pricing
    Book a RepairCall 0482 085 538
    Inside the line, we service it. Just outside? Give us a call and we will let you know.
    Our Service Area

    Servicing the Macedon Ranges and central Victoria

    Our service area runs along the Hume Highway up to Broadford, west across to Heathcote and Castlemaine, down through Daylesford, Creswick and Ballarat, then across Meredith, Bacchus Marsh and Melton, and back to Sunbury. Everything inside this line, we do. Sitting just outside it? Give us a call and we will let you know.

    Check your suburb

    Authorised Brivis & Rinnai dealer

    We are an authorised Brivis and Rinnai dealer and a Rinnai Trusted Climate Specialist. We buy direct from the manufacturer, our technicians are factory trained on their equipment, and we carry genuine parts on the van rather than whatever fits.

    Rinnai Trusted Climate SpecialistRinnaiBrivis by Rinnai
    What our customers say
    Real reviews from Macedon Ranges homes
    Read our Google reviews