Common faults
Ducted Air Conditioning Problems: Zones, Airflow and Temperature Explained
Zones not working, weak airflow, not reaching temperature or a controller fault. What each usually means for a ducted reverse cycle system, and when to book.
Updated 13 September 2026 by the Macedon Ranges Gas & Air team
The safe checks first
- Controller settings. Mode, set temperature and which zones are open. It is common for a zone to have been closed on the controller and forgotten.
- Return air filter. The large return grille has a filter behind it. If it is clogged, airflow drops everywhere. Clean or replace it as the manual describes if you can reach it safely.
- Outlets. Are the ceiling or floor outlets open and not covered by furniture or rugs?
- Power. Isolator at the outdoor unit and the circuit breaker.
Do not enter the roof space to inspect ductwork or open the indoor unit.
One zone not working
A zone motor or damper that has failed or stuck, a controller setting, or a wiring fault between the controller and the zone. If the zone was fine and has stopped, a zone motor is the usual suspect.
Weak airflow everywhere
A blocked return air filter, a dirty indoor coil, a fan problem, or ductwork that has collapsed, disconnected or been crushed in the roof. On systems that were connected to old ductwork, undersized or leaking ducts are a design fault rather than a breakdown, and no repair fixes that; see why new ductwork matters.
Not reaching temperature
Restricted airflow, a dirty outdoor coil, a refrigerant leak, a sensor reading the wrong place, or a system that was undersized for the house in the first place. We tell you which it is; an undersized system is a conversation about design, not a part.
Controller faults and error codes
Most ducted controllers show a code when they detect a fault. Note it down before you call; it tells our technician where to start.
What we do
A local technician diagnoses the actual fault and repairs it where practical on the day. We service and repair all major ducted brands, and we are factory-trained dealers for ActronAir and Rinnai. If the underlying problem is design rather than a component, we explain what a properly designed system involves: the MRGA Standard.
Need it done?
Ducted Reverse Cycle Air Conditioning
Whole-home ducted reverse cycle heating and cooling designed and installed by our own team across the Macedon Ranges. ActronAir, Rinnai, Mitsubishi Electric, zoning.
Keep reading
Related guides
Evaporative Cooler Not Cooling? Common Faults Explained
Cooler blowing warm air, water leaking, fan or pump not running or poor airflow. What each usually means, what you can check safely, and when to book a repair.
Gas Ducted Heater Not Working? Common Faults Explained
Heater not starting, blowing cold air, cutting out or showing a fault code. What each symptom usually means, the safe checks you can make, and when to call us.
Split System Not Cooling, Not Heating or Leaking? Common Faults Explained
What it usually means when a split system stops cooling or heating, drips water, makes a new noise or shows an error code, safe checks, and when to book a repair.
Which Heating and Cooling System Is Right for My Home?
A guided walk through evaporative, gas ducted heating, splits, multi-head, ducted reverse cycle and VEU electric upgrades, so you understand the trade-offs first.
Get in touch
Book a repair
Tell us what the system is doing. A photo of the controller or the unit helps, but is not needed.
Prefer to talk? Call 1300 369 400, monday to friday 8:00am to 5:00pm, Saturday 9:00am to 1:00pm.