Braemar Ducted Heating Error Codes Explained
Every Braemar gas ducted heater fault code in plain English, what you can safely check yourself, and when to stop and book a licensed repair in the Macedon Ranges.
Updated 10 September 2026 by the Macedon Ranges Gas & Air team
Braemar heaters display a numbered error code when the control board detects a fault. The meanings below are the plain-English summaries we published on our original guide, drawn from manufacturer documentation. Flame rollout, ignition failure, pressure switch and overheat faults are common and often repaired on the first visit. If a code appears, turn the heater off at the controller and book a licensed technician.
Braemar error codes
| Code | What it usually means |
|---|---|
| Error 01 | Low pressure switch closed at start |
| Error 02 | Low pressure switch failed to close |
| Error 03 | Low pressure switch opened during run |
| Error 04 | Thermistor above 70°C during run |
| Error 05 | Thermistor short circuit or open circuit |
| Error 06 | Flame detected when not required |
| Error 07 | Ignition failure |
| Error 08 | Condensate pressure switch closed at start |
| Error 09 | Thermistor above 60°C during start |
| Error 10 | Heat exchanger over-temperature circuit 1 open |
| Error 11 | Loss of flame signal |
| Error 12 | High pressure switch closed at start |
| Error 13 | High pressure switch failed to close |
| Error 14 | High pressure switch opened during run |
| Error 15 | Thermistor in cool duct location or multiple over-temperature resets |
| Error 16 | Thermistor in cool duct location or multiple over-temperature resets |
| Error 17 | Condensate detected during run |
| Error 18 | Condensate detected during start |
| Error 19 | Heat exchanger over-temperature circuit 2 open |
| Error 20 | Flame rollout detected during start |
| Error 21 | Flame rollout detected during run |
| Error 22 | Supply voltage out of range |
| Error 23 | Room fan not running |
| Error 24 | Room fan running backwards |
| Error 25-29 | Data table flag incorrect or control data fault |
| Error 30 | Loom ID incorrect |
| Error 31 | Combustion air pressure detected before start |
| Error 32 | Combustion air pressure too low at start |
| Error 33 | High gas relay error |
| Error 34 | Low gas relay error |
| Error 35 | Flame rollout circuit check failed |
| Error 36 | Flame rollout loom disconnected or shorted to ground |
| Error 37 | Reset button stuck |
| Error 38 | Gas valve closed during run |
| Error 39 | Combustion air pressure sensor error |
| Error 45 | Combustion air pressure too low during run |
| Error 46 | Gas valve modulating coil outside range |
| Error 47 | Combustion pressure sensor communication error |
| Error 48 | Micro flame mismatch |
| Error 49 | Five lockouts within 15 minutes |
| Error 50 | MagIQtouch controller communication loss |
| Error 51 | Microprocessor 2 error found |
| Error 52 | System check memory error |
| Error 53 | Voltage rail error |
| Error 54-64 | Internal ICS or control board fault |
| Error 70 | Micro one reading 1 at start-up or flame circuit reading too high |
| Error 71 | Micro one reading 2 at start-up or flame circuit reading too high |
| Error 72 | ICS flame circuit error, microprocessor 2 |
| Error 73 | Ripple value too high at start-up or flame sense reading too high |
| Error 74 | Micro one reading 1 after pre-purge or flame sense reading too high |
| Error 75 | Micro one reading 2 after pre-purge or flame sense reading too high |
| Error 76 | ICS flame circuit error, microprocessor 2 after pre-purge |
| Error 77 | Ripple value too high after pre-purge or flame sense reading too high |
| Error 78 | Micro one reading 1 during start-up or flame sense reading too high |
Before you do anything else
A fault code is the heater protecting itself. Most codes mean the control board has detected something outside its limits and shut the burner down. The safe things a homeowner can do are limited, and they are the same for every brand:
- Turn the heater off at the controller and leave it off for a minute or two, then turn it back on once. If the code returns, stop; repeated resetting can mask a fault the heater is trying to warn you about.
- Check the switchboard for a tripped circuit and check that the heater’s isolator has not been switched off.
- Check the return air filter. A badly blocked filter causes overheat and airflow faults on every brand. Clean or replace it if it is dirty.
- Do not open the heater, touch gas fittings, wiring or the flue, or attempt any repair yourself. Gas heater faults need a licensed technician.
- If you smell gas, turn the heater off, turn off the gas at the meter if you can, open windows, do not operate electrical switches near the smell, and call your gas distributor’s emergency line before anyone else.
When to stop and book a repair
Any code that comes back after one reset. Any flame, ignition, gas valve, overheat, rollout or flue-related code, first time. Any code accompanied by a smell, soot marks around the unit, headaches while the heater runs, or a heater that keeps cutting out. Tell us the brand, the code and what the unit is doing when you book a repair and the technician arrives with the likely parts.
Other brands
Brivis and Rinnai error codes, Bonaire error codes, or the error code hub. See also our Braemar page and gas ducted heating service.
Need it done?
Gas Ducted Heating Repairs
Heater not starting, blowing cold or showing a fault code? Licensed in-house technicians repair Brivis, Rinnai, Braemar and Bonaire heaters across the Ranges.
Keep reading
Related guides
Bonaire Ducted Heating Error Codes Explained
Every Bonaire gas ducted heater fault code in plain English, what you can safely check yourself, and when to stop and book a licensed repair in the Macedon Ranges.
Brivis and Rinnai Ducted Heating Error Codes Explained
Every Brivis and Rinnai ducted gas heater error code in plain English, plus older Buffalo and Wombat flash codes, what to safely check and when to book a repair.
Heater Error Codes Explained by Brand
Got a code flashing on your ducted heater controller? Pick your brand for every code explained in plain English, the safe checks you can do and when to call us.
Gas Ducted Heater Not Working? Common Faults Explained
Heater not starting, blowing cold air, cutting out or showing a fault code. What each symptom usually means, the safe checks you can make, and when to call us.
Get in touch
Book a repair
Tell us what the system is doing. A photo of the controller or the unit helps, but is not needed.
Prefer to talk? Call 1300 369 400, monday to friday 8:00am to 5:00pm, Saturday 9:00am to 1:00pm.