Brivis is part of the Rinnai group and Rinnai directs its ducted gas heater code support to the Brivis list, so the two brands share the same codes. The meanings below are the plain-English summaries we published on our original guide, drawn from manufacturer documentation. Flame failure, overheat lockouts and pressure switch faults are the codes we see most through a Ranges winter, and most are repaired on the first visit because we are factory-trained dealers for Brivis and Rinnai and carry the common parts.
If your controller is showing a code, switch the heater off and book a licensed technician. Gas faults should never be left running.
Brivis and Rinnai error codes
| Code | What it usually means |
|---|---|
| Error 30 | Fan limp mode or fan speed sensing fault |
| Error 31 | Flame rollout during ignition |
| Error 32 | Data error or stored parameter data fault |
| Error 33 | Modulating gas valve open circuit |
| Error 35 | Supply air thermistor open or short circuit |
| Error 36 | Bad supply air thermistor location or thermistor issue |
| Error 37 | Fan speed sensor or tacho error |
| Error 40 | Return air overheat or overheat condition |
| Error 41 | Supply air overheat |
| Error 42 | Supply air thermistor overheat |
| Error 43 | Overheat cooldown mode |
| Error 44 | Flame rollout detected |
| Error 45 | Low 24V AC supply |
| Error 46 | No flame on ignition or failed to light |
| Error 47 | Unstable flame or failed flame validation |
| Error 48 | Pressure lost during heating cycle |
| Error 49 | Flame lost during heating cycle |
| Error 50 | Ignition lockout after multiple ignition attempts |
| Error 51 | Rollout or flame signal detected when no gas should be present |
| Error 52 | False flame signal with gas valve off |
| Error 53 | Overheat lockout from multiple overheat events |
| Error 54 | Rollout lockout |
| Error 55 | Flame validation lockout or ignition failure |
| Error 56 | Pressure switch lockout, flue restriction or condensate blockage on SP6 models |
| Error 57 | Pressure switch stuck closed |
| Error 58 | Pressure switch fail or excessive pressure loss |
| Error 59 | Cross-check communication error between control processors |
| Error 60 | Motor open circuit |
| Error 61 | Primary gas valve stuck off |
| Error 62 | Primary gas valve stuck on |
| Error 63 | Primary gas valve failure |
| Error 64 | Modulating gas valve overcurrent |
| Error 65 | Motor lockout |
| Error 66 | Secondary gas valve stuck off |
| Error 67 | Secondary gas valve stuck on |
| Error 68 | Secondary gas valve failure |
| Error 69 | 24V fuse blown or 24V supply lost |
| Error 70 | Remote microcontroller shutdown fail |
| Error 71 | Remote microcontroller state mismatch |
| Error 72 | Ambiguous control fault |
| Error 73 | Remote microcontroller sequence error |
| Error 74 | Remote microcontroller lockout |
| Error 75 | 24V AC input scan fault |
| Error 76 | Lockout storage fault |
| Error 77 | Remote microcontroller I/O mismatch |
| Error 78 | Remote microcontroller I/O mismatch |
| Error 79 | A/D converter error |
| Error 80 | Flame sense fault |
| Error 81 | Rollout sense fault |
| Error 82 | System timing fault |
| Error 83 | Internal MCU execution fault |
| Error 84 | Control board lockout |
| Error 85 | Control board lockout |
| Error 86 | Control board lockout |
| Error 87 | Cross-check communications fault or no communication with remote MCU |
| Error 88 | Control board lockout |
| Error 89 | Non-volatile lockout storage test code, should not normally appear |
Older Brivis Buffalo and Wombat flash codes
Older Brivis Buffalo and Wombat heaters show faults as a number of flashes on the controller rather than a code number.
| Code | What it usually means |
|---|---|
| 1 flash | Overheat condition |
| 2 flashes | Multiple overheats or overheat lockout |
| 3 flashes | Flame rollout |
| 4 flashes | Multiple rollouts or rollout lockout |
| 5 flashes | Safe start lockout |
| 6 flashes | Ignition invalid or ignition lockout |
| 7 flashes | Gas valve failure or lockout |
| 8 flashes | Frequency fault or lockout |
Before you do anything else
A fault code is the heater protecting itself. Most codes mean the control board has detected something outside its limits and shut the burner down. The safe things a homeowner can do are limited, and they are the same for every brand:
- Turn the heater off at the controller and leave it off for a minute or two, then turn it back on once. If the code returns, stop; repeated resetting can mask a fault the heater is trying to warn you about.
- Check the switchboard for a tripped circuit and check that the heater’s isolator has not been switched off.
- Check the return air filter. A badly blocked filter causes overheat and airflow faults on every brand. Clean or replace it if it is dirty.
- Do not open the heater, touch gas fittings, wiring or the flue, or attempt any repair yourself. Gas heater faults need a licensed technician.
- If you smell gas, turn the heater off, turn off the gas at the meter if you can, open windows, do not operate electrical switches near the smell, and call your gas distributor’s emergency line before anyone else.
When to stop and book a repair
Any code that comes back after one reset. Any flame, ignition, gas valve, overheat, rollout or flue-related code, first time. Any code accompanied by a smell, soot marks around the unit, headaches while the heater runs, or a heater that keeps cutting out. Tell us the brand, the code and what the unit is doing when you book a repair and the technician arrives with the likely parts.
Other brands
Braemar error codes, Bonaire error codes, or the error code hub. For the systems themselves, see our Brivis and Rinnai pages and gas ducted heating service.
Need it done?
Gas Ducted Heating Repairs
Heater not starting, blowing cold or showing a fault code? Licensed in-house technicians repair Brivis, Rinnai, Braemar and Bonaire heaters across the Ranges.
Keep reading
Related guides
Bonaire Ducted Heating Error Codes Explained
Every Bonaire gas ducted heater fault code in plain English, what you can safely check yourself, and when to stop and book a licensed repair in the Macedon Ranges.
Braemar Ducted Heating Error Codes Explained
Every Braemar gas ducted heater fault code in plain English, what you can safely check yourself, and when to stop and book a licensed repair in the Macedon Ranges.
Heater Error Codes Explained by Brand
Got a code flashing on your ducted heater controller? Pick your brand for every code explained in plain English, the safe checks you can do and when to call us.
Gas Ducted Heater Not Working? Common Faults Explained
Heater not starting, blowing cold air, cutting out or showing a fault code. What each symptom usually means, the safe checks you can make, and when to call us.
Get in touch
Book a repair
Tell us what the system is doing. A photo of the controller or the unit helps, but is not needed.
Prefer to talk? Call 1300 369 400, monday to friday 8:00am to 5:00pm, Saturday 9:00am to 1:00pm.